Saturday, February 21, 2009

Solvant Extraction

SOLVANT EXTRACTION:

 

Solvent extraction and partitioning, is a method to separate compounds based on their relative solubilities in two different immiscible liquids, usually water and an organic solvent.

Distribution Law:

This law stats that a soute distributes itself between two immiscible liquids in a constant ratio irrespective of the amount of the solute added.

Distribution ratio

In solvent extraction, a distribution ratio is often quoted as a measure of how well-extracted a species is. The distribution ratio (D) is equal to the concentration of a solute in the organic phase divided by its concentration in the aqueous phase. Depending on the system, the distribution ratio can be a function of temperature, the concentration of chemical species in the system, and a large number of other parameters.

Note that D is related to the ΔG of the extraction process.

Separation factors

The separation factor is one distribution ratio divided by another, it is a measure of the ability of the system to separate two solutes. For instance, if the distribution ratio for nickel (DNi) is 10 and the distribution ratio for silver (DAg) is 100, then the silver/nickel separation factor (SFAg/Ni) is equal to DAg/DNi = SFAg/Ni = 10.

Decontamination factor

This is used to express the ability of a process to remove a contaminant from a product. For instance, if a process is fed with a mixture of 1:9 cadmium to indium, and the product is a 1:99 mixture of cadmium and indium then the decontamination factor (for the removal of cadmium) of the process is 0.1 / 0.01 = 10.

Techniques

Batch wise single stage extractions

This is commonly used on the small scale in chemical labs. It is normal to use a separating funnel. For instance, if a chemist was to extract anisole from a mixture of water and 5% acetic acid using ether, then the anisole will enter the organic phase. The two phases would then be separated.

The acetic acid can then be scrubbed (removed) from the organic phase by shaking the organic extract with sodium bicarbonate. The acetic acid reacts with the sodium bicarbonate to form sodium acetate, carbon dioxide, and water.

Multistage countercurrent continuous processes

These are commonly used in industry for the processing of metals such as the lanthanides, because the separation factors between the lanthanides are so small many extraction stages are needed. In the multistage processes the aqueous raffinate from one extraction unit is feed as the next unit as the aqueous feed. While the organic phase is moved in the opposite direction. Hence in this way even if the separation between two metals in each stage is small, the overall system can have a higher decontamination factor.

Extraction without chemical change

Some solutes such as noble gases can be extracted from one phase to another without the need for a chemical reaction. This is the most simple type of solvent extraction. Some solutes which do not at first sight appear to undergo a reaction during the extraction process do not have distribution ratio which is independent of concentration. A classic example is the extraction of carboxylic acids (HA) into non polar media such as benzene. Here it is often the case that the carboxylic acid will form a dimer in the organic layer so the distribution ratio will change as a function of the acid concentration (measured in either phase).

For this case the extraction constant k is described by k = [[HAorganic]]2/[[HAaqueous]]

Solvation mechanism

Using solvent extraction it is possible to extract uranium, plutonium, or thorium from acid solutions. One solvent used for this purpose is the organophosphate tri-n-butyl phosphate. The PUREX process is commonly used in nuclear reprocessing uses a mixture of tri-n-butyl phosphate and an inert hydrocarbon the uranium(VI) are extracted from strong nitric acid and are back-extracted (stripped) using weak nitric acid. An organic soluble uranium complex [UO2(TBP)2(NO3)2] is formed, then the organic layer bearing the uranium is brought into contact with a dilute nitric acid solution the equilibrium is shifted away from the organic soluble uranium complex and towards the free TBP and uranyl nitrate in dilute nitric acid. The plutonium(IV) forms a similar complex to the uranium(VI) but it is possible to strip the plutonium in more than one way, a reducing agent can be added which converts the plutonium to the trivalent oxidation state. This oxidation state does not form a stable complex with TBP and nitrate unless the nitrate concentration is very high (circa 10 mol/L nitrate is required in the aqueous phase). Another method is to simply use dilute nitric acid as a stripping agent for the plutonium. This PUREX chemistry is a classic example of a solvation extraction.

Ion exchange mechanism

Another extraction mechanism is known as the ion exchange mechanism. Here when an ion is transferred from the aqueous phase to the organic phase, another ion is transferred in the other direction to maintain the charge balance. This additional ion is often a hydrogen ion, for ion exchange mechanisms the distribution ratio is often a function of pH. An example of an ion exchange extraction would be the extraction of americium by a combination of terpyridine and a carboxylic acid in tert-butyl

Ion pair extraction

It is possible by careful choice of counterion to extract a metal. For instance, if the nitrate concentration is high it is possible to extract americium as an anionic nitrate complex if the mixture contains a lipophilic quaternary ammonium salt.

An example which is more likely to be encountered by the 'average' chemist is the use of a phase transfer catalyst, these are charged species which transfer another ion to the organic phase. The ion reacts and then forms another ion which is then transferred back to the aqueous phase.

Aqueous two phase extraction

Using an Aqueous two phase system, it is possible to generate two immiscible water phases. This can then be used to extract proteins, which would denature if exposed to organic solvents.

Solid phase Extraction

SOLID PHASE EXTRACTION

Solid-phase extraction (SPE) is a separation process that is used to remove certain compounds from a mixture of impurities based on their physical and chemical properties. Analytical laboratories use solid phase extraction to concentrate and purify samples for analysis. Solid phase extraction can be used to isolate analytes of interest from a wide variety of matrices, including urine, blood, water samples, beverages, soil, animal tissue, and consumer products.

SPE uses the affinity of solutes dissolved or suspended in a liquid solid through which the sample is passed (known as the stationary phase) to separate a mixture into desired and undesired components. The result is that either the desired analytes of interest or undesired impurities in the sample are retained on the stationary phase. The portion that passes through the stationary phase is collected or discarded, depending on whether it contains the desired analytes or undesired impurities. If the portion retained on the stationary phase includes the desired analytes, they can then be removed from the stationary phase for collection in an additional step, in which the stationary phase is rinsed with an appropriate eluent.

The stationary phase comes in the form of a packed syringe-shaped cartridge, a 96 well plate or a 47- or 90-mm flat disk, which can be mounted on a commercially available extraction manifold. The manifold allows many samples to be processed simultaneously. A typical cartridge SPE manifold can accommodate up to 24 cartridges, while a typical disk SPE manifold can accommodate 6 disks. Most SPE manifolds are equipped with a vacuum port. Application of vacuum speeds up the extraction process by pulling the liquid sample through the stationary phase. The analytes are collected in sample tubes inside or below the manifold after they pass through the stationary phase.

Solid phase extraction cartridges and disks are available with a variety of stationary phases, each of which can separate analytes according to different chemical properties. Most stationary phases are based on silica that has been bonded to a specific functional group. Some of these functional groups include hydrocarbon chains of variable length (for reversed phase SPE), quaternary ammonium or amino groups (for anion exchange), and sulfonic acid or carboxyl groups (for cation exchange).[

A typical solid phase extraction involves four basic steps. First, the cartridge is equilibrated with a non-polar solvent or slightly polar, which wets the surface and penetrates the bonded phase. Then water, or buffer of the same composition as the sample, is typically washed through the column to wet the silica surface. The sample is then added to the cartridge. As the sample passes through the stationary phase, the analytes in the sample will interact and retain on the sorbent while the solvent, salts, and other impurities pass through the cartridge. After the sample is loaded, the cartridge is washed with buffer or solvent to remove further impurities. Then, the analyte is eluted with a non-polar solvent or a buffer of the appropriate pH.

A stationary phase of polar functionally bonded silicas with short carbons chains frequently makes up the solid phase. This stationary phase will adsorb polar molecules which can be collected with a more polar solvent.

Reversed phase SPE

Reversed phase SPE separates analytes based on their polarity. The stationary phase of a reversed phase SPE cartridge is derivatized with hydrocarbon chains, which retain compounds of mid to low polarity due to the hydrophobic effect. The analyte can be eluted by washing the cartridge with a non-polar solvent, which disrupts the interaction of the analyte and the stationary phase.

A stationary phase of silicon with carbon chains is commonly used. Relying on mainly non-polar, hydrophobic interactions, only non-polar or very weakly polar compounds will adsorb to the surface.

Ion exchange SPE

Ion exchange sorbents separate analytes based on electrostatic interactions between the analyte of interest and the positively charged groups on the stationary phase. For ion exchange to occur, both the stationary phase and sample must be at a pH where both are charged.

Anion exchange

Anion exchange sorbents are derivatized with positively charged functional groups that interact and retain negatively charged anions, such as acids. Strong anion exchange sorbents contain quaternary ammonium groups that have a permanent positive charge in aqueous solutions, and weak anion exchange sorbents use amine groups which are charged when the pH is below about 9. Strong anion exchange sorbents are useful because any strongly acidic impurities in the sample will bind to the sorbent and usually will not be eluted with the analyte of interest; to recover a strong acid a weak anion exchange cartridge should be used. To elute the analyte from either the strong or weak sorbent, the stationary phase is washed with a solvent that neutralizes the charge of either the analyte, the stationary phase, or both. Once the charge is neutralized, the electrostatic interaction between the analyte and the stationary phase no longer exists and the analyte will elute from the cartridge.

Cation Exchange

Cation exchange sorbents are derivatized with functional groups that interact and retain positively charged cations, such as bases. Strong cation exchange sorbents contain aliphatic sulfonic acid groups that are always negatively charged in aqueous solution, and weak cation exchange sorbents contain aliphatic carboxylic acids, which are charged when the pH is above about 5. Strong cation exchange sorbents are useful because any strongly basic impurities in the sample will bind to the sorbent and usually will not be eluted with the analyte of interest; to recover a strong base a weak cation exchange cartridge should be used. To elute the analyte from either the strong or weak sorbent, the stationary phase is washed with a solvent that neutralizes ionic interaction between the analyte and the stationary phase. 

Fluorapatite

FLUORAPATITE:


Production

Fluorapatite can be synthesized in a two step process. First, calcium phosphate is generated by combining calcium and phosphate salts at neutral pH.This material then reacts further with fluoride sources (often sodium monofluorophosphate or calcium fluoride (CaF2)) to give the mineral. This reaction is integral in the global phosphorus cycle

3Ca2+ + 2PO43- → Ca3(PO4)2

3 Ca3(PO4)2 + CaF2 → 2 Ca5(PO4)3F

Application

Fluorapatite can be used as a precursor for the production of phosphorus. The mineral can be reduced by carbon in the presence of quartz, ultimately generating white phosphorus, P4:

Ca5(PO4)3F + 3SiO2 + 5C → 3CaSiO3 + 5CO + P2

2P2 → P4 after cooling.


Cryolite

CRYOLITE

Cryolite (Na3AlF6, sodium hexafluoroaluminate) is an uncommon mineral identified with the once large deposit at Ivigtût on the west coast of Greenland, which ran out in 1987.

It was historically used as an ore of aluminium and later in the electrolytic processing of the aluminium-rich oxide ore bauxite (itself a combination of aluminium oxide minerals such as gibbsite, boehmite and diaspore). The difficulty of separating aluminium from oxygen in the oxide ores was overcome by the use of cryolite as a flux to dissolve the oxide mineral(s). Cryolite itself melts below 900°C (1173 Kelvin), and it can dissolve the aluminium oxides sufficiently well to allow easy extraction of the aluminium by electrolysis. Considerable energy is still required for both heating the materials and the electrolysis, but it is much more energy-efficient than melting the oxides themselves. Now, as natural cryolite is too rare to be used for this purpose, synthetic sodium aluminium fluoride is produced from the common mineral fluorite for this purpose.

Occurrence

Cryolite occurs as glassy, colorless, white-reddish to grey-black prismatic monoclinic crystals. It has a Mohs hardness of 2.5 to 3 and a specific gravity of about 2.95 to 3.0. It is translucent to transparent with very low refractive indices of a=1.3385–1.339, b=1.3389–1.339, g=1.3396–1.34. These RI values are very close to that of water, and thus if it is immersed in water, cryolite becomes essentially invisible.

Cryolite has also been reported at Pikes Peak, Colorado; Mont Saint-Hilaire, Quebec; and at Miass, Russia. It is also known in small quantities in Brazil, the Czech Republic, Namibia, Norway,Ukraine, and several American states.

Uses

1) It is used as a whitener for enamel and an opacifier in glass

2) Cryolite has been used as a pesticide.

3) It is used in the smelting of aluminium and production of enamelss

4) It is used as a flux in order to extract the aluminium metal.

5) It is used as a flux to dissolve the oxide.


Hydrogen Fluoride

HYDROGEN FLUORIDE:


PRODUCTION:

Hydrogen Fluoride is manufactured from fluorosilicic acid. The fluorosilicic acid is reacted with ammonia to produce aqueous ammonium fluoride and solid silica. The ammonium fluoride is hydrolyzed in the presence of a mixture of ammonium fluoride and ammonium bifluoride, and the net production of ammonium bifluoride is converted to sodium bifluoride. The sodium bifluoride is decomposed by heating to hydrogen fluoride gas.



USES:

1) HF is used for fluorinating polymers giving fluorocarbons, petroleum refining, glassmaking, aluminium manufacturing, titanium pickling, quartz purification, and metal finishing.

2) It is also used to synthesize UF6, which is a key to separating uranium isotopes.

3) Hydrogen fluoride can be found in consumer products for removing rust, cleaning brass, and glass etching, although use in consumer products is discourage due to HF's corrosiveness and toxicity.

Hydrogen fluoride is typically marketed in three common forms: anhydrous HF, aqueous 70% HF, aqueous 49% HF. HF is manufactured by the reaction of calcium fluoride (fluorspar) and sulfuric acid:
CaF2 + H2SO4 → CaSO4 + 2 HF
The vapors from this reaction are a mixture of hydrogen fluoride, sulfuric acid, and a few minor byproducts.

fluorspar

FLUORSPAR

Fluorspar is a mineral composed of calcium fluoride, CaF2. It is an isometric mineral with a cubic habit.
PRODUCTION

In the production of fluorspar, hexafluorosilicic acid is reacted with calcium carbonate, and the resulting calcium fluoride is filtered off, the improvement which comprises effecting the reaction by adding hexafluosilicic acid to an aqueous suspension of the calcium carbonate at a temperature of about 0° to 40°C, there being present during the reaction at least about 3 times as much water by weight as calcium In the production of synthetic fluorspar aqueous hexafluosilicic acid is reacted with carbonate. Advantageously the reaction is effected in a plurality of stages, in the first of which the calcium carbonate suspension is reacted with a stoichiometric excess of hexafluosilicic acid up to a pH of about 2 to 3, and after a residence time of about 5 to 30 minutes the pH is adjusted to about 4 to 6 in the second stage by the addition of calcium carbonate.




Uses
It has many applications.

1) It has been used as a flux to lower the melting point of raw materials in steel production to aid the removal of impurities.
2) fluorite is used in the manufacture of opalescent glass, enamels and cooking utensils.
3) Fluorite is used instead of glass in some high performance telescopes and camera lens elements.
4) Their transparency to ultraviolet light enables them to be used for fluorescence microscopy.
5) The fluorite also serves to correct optical aberrations in these lenses.

Monday, February 16, 2009

Chromatography

CHROMATOGRAPHY:
It is a technique used for separating a sample of mixture.
TYPES OF CHROMATOGRAPHY:
  1. Partition chromatography
  2. Adsorption chromatography
Partition Chromatography:
The type of chromatography in which stationary phase is liquid is called partition chromatography.

Adsorption Chromatographt:
The type of chromatography in which stationary phase is solid is called adsorption chromatography.

Stationary Phase:
The stationary phase may be a solid or a liquid supported as a thin film on the surface of an inert solid.

Mobile Phase:
The mobile phase flowing over the surface of the stationary phase may be a liquid or a gas.

Types of Chromatography

  1. Thin layer Chromatography
  2. Paper Chromatography
  3. Column Chromatography
  4. Gas Chromatography
  5. High Performance liquid Chromatigraphy
Thin Layer Chromatography(Adsorbtion Chromatography):
    TLC is a technique used to separate mixtures.
Stationary Phase:
A finaly ground powder of silica,alumina or similar material is used as a stationary phase.
Mobile Phase:
The mobile phase is any volatile solvent.
Preparation of plate:
 These plates are prepared by mixing silica gel with a small amount of inert binder like gypsum and water.This mixture is spread as a thick slurry on an unreactive carrier sheet usually glass like aluminium foil and water.
Thickness of the adsorbent layer is typically around 0.1–0.25 mm for analytical purposes and around 1–2 mm for preparative TLC.
Procedure:
The sample, either liquid or dissolved in a volatile solvent, is deposited as a spot on the stationary phase. The bottom edge of the plate is placed in a solvent reservoir, and the solvent moves up the plate by capillary action. When the solvent front reaches the other edge of the stationary phase, the plate is removed from the solvent reservoir. The separated spots are visualized with ultraviolet light or by placing the plate in iodine vapor. The different components in the mixture move up the plate at different rates due to differences in their partioning behavior between the mobile liquid phase and the stationary phase.
Rf Value:

The retention factor, or Rf, is defined as the distance traveled by the compound divided by the distance traveled by the solvent.


Paper Chromatography

 It is a type of partition chromatography 

 Stationart Phase:

 Stationary phase in paper chromatography is a liquid e.g water absorbed on paper.

 Mobile Phase:

 The mobile phase is usually an organic solvant.

 Procedure:

  • A drop of mixture is placed in one corner of a square of absorbent paper.
  • One edge of the paper is immersed in a solvent. (a)
  • The solvent migrates up the sheet by capillary attraction.
  • As it does so, the substances in the drop are carried along at different rates. (b)
  • Each compound migrates at a rate that reflects
    • the size of its molecule and
    • its solubility in the solvent.
  • After a second run at right angles to the first (often using a different solvent), the various substances will be spread out at distinct spots across the sheet, forming a chromatogram. (c)
  • The identity of each spot can be determined by comparing its position with the position occupied by known substances under the same conditions.
  • In many cases, a fragment of the paper can be cut away from the sheet and chemical analysis run on the tiny amount of substance in it.

   Rf values:

   The distance travelled relative to the solvent is called the Rf value. For each compound it can be     worked out using the formula:

 For example, if one component of a mixture travelled 9.6 cm from the base line while the solvent  had travelled 12.0 cm, then the Rfvalue for that component is:

Sunday, February 15, 2009

Column Chromatography

  It is an adsorption chromatography.
      It is a method used to purify individual chemical compounds from mixtures of compounds.
Stationary Phase:
The stationary phase or adsorbent in column chromatography is a solid. The most common stationary phase for column chromatography is silica gel.
Mobile Phase:
The mobile phase is either a pure solvent or a mixture of different solvents. 
Columns:
Columns for chromatography can be small or big, according to the amount of material which needs to be loaded onto the column.
The classical preparative chromatography column is a glass tube with a diameter from 5-50 mm and a height of 50cm to 1 m.
Procedure:

Suppose you wanted to separate a mixture of two coloured compounds - one yellow, one blue. The mixture looks green.

You would make a concentrated solution of the mixture preferably in the solvent used in the column.

First you open the tap to allow the solvent already in the column to drain so that it is level with the top of the packing material, and then add the solution carefully to the top of the column. Then you open the tap again so that the coloured mixture is all absorbed into the top of the packing material,

Next you add fresh solvent to the top of the column, trying to disturb the packing material as little as possible. Then you open the tap so that the solvent can flow down through the column, collecting it in a beaker or flask at the bottom. As the solvent runs through, you keep adding fresh solvent to the top so that the column never dries out.

Explaining what is happening:

The blue compound is more polar than the yellow. it perhaps even has the ability to hydrogen bond. We can tell this because the blue compound doesn't travel through the column very quickly. That means that it must adsorb more strongly to the silica gel or alumina than the yellow one. The less polar yellow one spends more of its time in the solvent and therefore washes through the column much faster.

Elution and eluent:

The process of washing a compound through a column using a solvent is known as elution. The solvent is sometimes known as the eluent.

Saturday, February 14, 2009

Gas Chromatography

 It is column chromatography.
   It is a common type of chromatography used in organic chemistry for separating and analyzing compounds that can be vapourized without decomposition.
Stationary Phase:
The stationary phase is a layer of liquid or polymer on an inert solid support inside a glass or metal tubing called a column.
Mobile Phase:
The mobile phase is a carrier gas usually an innert gas such as helium or an unreactive gas such as oxygen.
Differences from Column chromatography:
  • Stationary phase is liquid.In Column chromatography it is solid.
  • Mobile phase is Gas. It is liquid in Column chromatography.
  • Temperature is controlled in an oven where as in GC there is no temperature control.
Procedure:
In a GC analysis, a known volume of gaseous or liquid analyte is injected into the "entrance" (head) of the column, usually using a microsyringe(or, solid phase microextraction fibers, or a gas source switching system). As the carrier gas sweeps the analyte molecules through the column, this motion is inhibited by the adsorption of the analyte molecules either onto the column walls or onto packing materials in the column. The rate at which the molecules progress along the column depends on the strength of adsorption, which in turn depends on the type of molecule and on the stationary phase materials. Since each type of molecule has a different rate of progression, the various components of the analyte mixture are separated as they progress along the column and reach the end of the column at different times (retention time). A detector is used to monitor the outlet stream from the column; thus, the time at which each component reaches the outlet and the amount of that component can be determined. Generally, substances are identified (qualitatively) by the order in which they emerge (elute) from the column and by the retention time of the analyte in the column.